Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

CVE-2026-35504— Subnet Solutions PowerSYSTEM Center CRLF injection

Quick assessment

Affected
Subnet Solutions PowerSYSTEM Center 2020
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Subnet Solutions PowerSYSTEM Center是Subnet Solutions公司的一个电力解决方案。 Subnet Solutions PowerSYSTEM Center存在注入漏洞,该漏洞源于使用SMTPS通信时存在CRLF注入。

CVSS 5.5 · Medium EPSS 0.31% · P21

Possible ATT&CK Techniques 1 AI

T1190 · Exploit Public-Facing Application

Affected Version Matrix 3

VendorProduct Version RangeStatus
Subnet Solutions PowerSYSTEM Center 2020 ≤ 5.28.x affected
Subnet Solutions PowerSYSTEM Center 2024 6.0.x≤ 6.1.x affected
Subnet Solutions PowerSYSTEM Center 2026 7.0.x affected
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-35504

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Subnet Solutions PowerSYSTEM Center CRLF injection
Source: CVE Program / CVE List V5
Vulnerability Description
PowerSYSTEM Center email notification service is affected by a CRLF injection vulnerability when using SMTPS communication.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Source: CVE Program / CVE List V5
Vulnerability Type
对CRLF序列的转义处理不恰当(CRLF注入)
Source: CVE Program / CVE List V5
Vulnerability Title
Subnet Solutions PowerSYSTEM Center 注入漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Subnet Solutions PowerSYSTEM Center是Subnet Solutions公司的一个电力解决方案。 Subnet Solutions PowerSYSTEM Center存在注入漏洞,该漏洞源于使用SMTPS通信时存在CRLF注入。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Subnet Solutions PowerSYSTEM Center 2020 0 ~ 5.28.x -
Subnet Solutions PowerSYSTEM Center 2024 6.0.x ~ 6.1.x -
Subnet Solutions PowerSYSTEM Center 2026 7.0.x -

II. Public POCs for CVE-2026-35504

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-35504

请登录查看更多情报信息。

Vendor Advisories for CVE-2026-35504 (2)

Same Patch Batch · Subnet Solutions · 2026-05-12 · 4 CVEs total

CVE-2026-26289 8.2 HIGH Subnet Solutions PowerSYSTEM Center Incorrect Authorization
CVE-2026-35555 6.3 MEDIUM Subnet Solutions PowerSYSTEM Center Incorrect Authorization
CVE-2026-33570 5.7 MEDIUM Subnet Solutions PowerSYSTEM Center Incorrect Authorization

IV. Related Vulnerabilities

V. Comments for CVE-2026-35504

No comments yet


Leave a comment