Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2026-50062

Quick assessment

Affected
Siemens Solid Edge SE2025
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Siemens Solid Edge SE2025是德国Siemens公司的一套三维产品设计与工程软件。 Siemens Solid Edge SE2025 V225.0 Update 15之前版本和Solid Edge SE2026 V226.0 Update 7之前版本存在缓冲区错误漏洞,该漏洞源于解析特制PAR文件时存在越界读取,可能导致攻击者在当前进程上下文中执行代码。

CVSS 7.8 · High EPSS 0.11% · P2

Possible ATT&CK Techniques 1 AI

T1203 · Exploitation for Client Execution

Affected Version Matrix 2

VendorProduct Version RangeStatus
Siemens Solid Edge SE2025 < V225.0 Update 15 affected
Siemens Solid Edge SE2026 < V226.0 Update 7 affected
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-50062

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Source: CVE Program / CVE List V5
Vulnerability Type
跨界内存读
Source: CVE Program / CVE List V5
Vulnerability Title
Siemens Solid Edge SE2025 缓冲区错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Siemens Solid Edge SE2025是德国Siemens公司的一套三维产品设计与工程软件。 Siemens Solid Edge SE2025 V225.0 Update 15之前版本和Solid Edge SE2026 V226.0 Update 7之前版本存在缓冲区错误漏洞,该漏洞源于解析特制PAR文件时存在越界读取,可能导致攻击者在当前进程上下文中执行代码。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

Vendor Product Affected Versions CPE Subscribe
Siemens Solid Edge SE2025 0 ~ V225.0 Update 15 -
Siemens Solid Edge SE2026 0 ~ V226.0 Update 7 -

II. Public POCs for CVE-2026-50062

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-50062

登录查看更多情报信息。

Vendor Advisories for CVE-2026-50062 (1)

Same Patch Batch · Siemens · 2026-08-11 · 17 CVEs total

CVE-2026-58115 10.0 CRITICAL Siemens SIMATIC IoT2050 Advanced 授权问题漏洞
CVE-2026-50058 7.8 HIGH Siemens Solid Edge SE2025 缓冲区错误漏洞
CVE-2026-50059 7.8 HIGH Siemens Solid Edge SE2025 缓冲区错误漏洞
CVE-2026-50060 7.8 HIGH Siemens Solid Edge SE2025 资源管理错误漏洞
CVE-2026-50061 7.8 HIGH Siemens Solid Edge SE2025 资源管理错误漏洞
CVE-2026-50063 7.8 HIGH Siemens Solid Edge SE2025 缓冲区错误漏洞
CVE-2026-50064 7.8 HIGH Siemens Solid Edge SE2025 缓冲区错误漏洞
CVE-2026-59086 7.8 HIGH Siemens Simcenter Nastran 缓冲区错误漏洞
CVE-2026-59700 7.8 HIGH Siemens Simcenter Femap 缓冲区错误漏洞
CVE-2026-59701 7.8 HIGH Siemens Simcenter Femap 缓冲区错误漏洞
CVE-2026-64629 7.8 HIGH Siemens Parasolid 缓冲区错误漏洞
CVE-2026-69109 7.5 HIGH Siemens License Server 路径遍历漏洞
CVE-2026-57262 6.8 MEDIUM Siemens LOGO! Soft Comfort 加密问题漏洞
CVE-2026-57263 6.8 MEDIUM Siemens LOGO! Soft Comfort 加密问题漏洞
CVE-2026-69108 6.0 MEDIUM Siemens License Server 权限许可和访问控制问题漏洞
CVE-2026-59693 4.3 MEDIUM Siemens Desigo DXR2 异常处理不当漏洞

IV. Related Vulnerabilities

V. Comments for CVE-2026-50062

No comments yet


Leave a comment