漏洞信息
尽管我们使用了先进的大模型技术,但其输出仍可能包含不准确或过时的信息。神龙努力确保数据的准确性,但请您根据实际情况进行核实和判断。
Vulnerability Title
N/A
Vulnerability Description
A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions running Example Image versions with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server.
This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Vulnerability Type
关键功能的认证机制缺失
Vulnerability Title
Siemens SIMATIC IoT2050 Advanced 授权问题漏洞
Vulnerability Description
Siemens SIMATIC IoT2050 Advanced是德国Siemens公司的一款物联网边缘计算网关设备。 Siemens SIMATIC IoT2050 Advanced V4.3.4.1之前版本存在授权问题漏洞,该漏洞源于Node-RED HTTP接口未实施身份验证,可能导致未经身份验证的远程攻击者通过HTTP接口创建恶意流程,从而在底层服务器上以最高权限执行任意代码。
CVSS Information
N/A
Vulnerability Type
N/A