Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2026-50606— Hard-coded Encryption Key Vulnerability in Acer System Monitoring for NitroSense and PredatorSense Software

Quick assessment

Affected
Acer System Monitoring
Exploitation
No confirmed in-the-wild exploitation; assess based on exposure
Recommended action
Check the vendor advisory and references for a fixed version. If immediate upgrade is impossible, restrict exposure and increase monitoring.

Acer 系统监控组件(随 NitroSense 和 PredatorSense 软件一起提供)中发现了一个安全漏洞。该漏洞是由软件中使用了硬编码的 AES 加密密钥所致。在特定情况下,本地攻击者可能利用该内置密钥访问受保护的信息或执行未经授权的操

CVSS 1.2 · Low

Possible ATT&CK Techniques 1 AI

T1552.001 · Credentials In Files
Get alerts for future matching vulnerabilities Log in to subscribe

I. Basic Information for CVE-2026-50606

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Hard-coded Encryption Key Vulnerability in Acer System Monitoring for NitroSense and PredatorSense Software
Source: CVE Program / CVE List V5
Vulnerability Description
A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions.
Source: CVE Program / CVE List V5
CVSS Information
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:U
Source: CVE Program / CVE List V5
Vulnerability Type
使用硬编码的密码学密钥
Source: CVE Program / CVE List V5

Affected Products

Vendor Product Affected Versions CPE Subscribe
Acer System Monitoring * ~ 1.0.19.2 -

II. Public POCs for CVE-2026-50606

# POC Description Source Link Shenlong Link
AI-Generated POC Premium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-50606

登录查看更多情报信息。

Same Patch Batch · Acer · 2026-09-17 · 8 CVEs total

CVE-2026-50605 7.4 HIGH Privilege Escalation Vulnerability in NitroSense and PredatorSense Software
CVE-2026-50609 7.4 HIGH Unauthorized Registry Modification Vulnerability in NitroSense and PredatorSense Software
CVE-2026-50610 7.4 HIGH Improper Access control Vulnerability in NitroSense and PredatorSense Software
CVE-2026-50603 4.9 MEDIUM Hard-coded encryption key vulnerability in Acer Agent Service for NitroSense and PredatorS
CVE-2026-50604 4.9 MEDIUM Unauthenticated Access Vulnerability in NitroSense and PredatorSense Software
CVE-2026-50607 2.7 LOW WebSocket Exposure Vulnerability in NitroSense and PredatorSense Software
CVE-2026-50608 1.2 LOW Authentication Vulnerability in NitroSense and PredatorSense Software

IV. Related Vulnerabilities

V. Comments for CVE-2026-50606

No comments yet


Leave a comment