Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1359 CNY

100%

Dräger — Vulnerabilities & Security Advisories 16

Browse all 16 CVE security advisories affecting Dräger. AI-powered Chinese analysis, POCs, and references for each vulnerability.

This page aggregates security vulnerabilities associated with the vendor Dräger. It collects publicly disclosed flaws affecting Dräger products, spanning a broad time range from recent releases to legacy systems. Readers can use this resource to track the vendor's security advisories, understand specific weakness classes within their product lines, or look up the historical vulnerability profile of particular devices. The data is organized to facilitate technical analysis rather than general awareness, providing a structured view of how security issues have emerged and been addressed over time. By examining these entries, users can identify patterns in implementation errors, configuration weaknesses, or protocol-level defects specific to Dräger's medical and industrial equipment. This aggregation serves as a reference point for security professionals assessing risk exposure, comparing remediation timelines across different product generations, and evaluating the overall maturity of the vendor's security response process. The focus remains on factual reporting of known issues, enabling stakeholders to make informed decisions regarding patch management and system hardening without relying on fragmented individual announcements.

CVE ID Title CVSS Severity Published
CVE-2019-25720 Dräger SC Monitoring Devices DoS via Malformed Network Packet — SC 6002XL CWE-1286 6.5 Medium 2026-06-03
CVE-2021-4481 Dräger Protector Software Local Privilege Escalation via Insecure File Permissions — Protector Software CWE-732 8.2 High 2026-06-02
CVE-2021-4480 Dräger Protector Software Local Privilege Escalation via Insecure File Permissions — Protector Software CWE-732 8.2 High 2026-06-02
CVE-2025-15653 Dräger Zeus IE Anesthesia Workstation USB Interface Privilege Escalation — Zeus IE CWE-668 6.8 Medium 2026-06-02
CVE-2024-14036 Dräger Core 1.0.5 Denial of Service via Malformed SDC Message — Core CWE-400 7.5 High 2026-06-02
CVE-2022-4992 Dräger Infinity M540 VG4.1.1 Spoofed Network Message Handling DoS/Tampering — Infinity Acute Care System CWE-345 8.6 High 2026-06-02
CVE-2021-4479 Dräger Atlan A350 1.00 <= 1.01 DoS via Medibus Interface — Atlan A350 CWE-1286 4.0 Medium 2026-06-02
CVE-2021-4478 Dräger CC-Vision Basic and CC-Vision E-Cal Out-of-Bounds Write via Malicious GDT File — CC-Vision Basic CWE-787 8.2 High 2026-06-02
CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service — Infinity M300 CWE-400 6.5 Medium 2026-06-02
CVE-2019-25723 Dräger Perseus A500 2.00-2.02 DoS via Medibus Interface — Perseus A500 CWE-1286 4.0 Medium 2026-06-02
CVE-2019-25722 Dräger SC Monitoring Devices Hard-coded Credentials and DoS — SC 6002XL CWE-798 7.6 High 2026-06-02
CVE-2019-25721 Dräger Infinity M300 VG2.3.1 Network-Based Denial of Service — Infinity M300 CWE-400 6.5 Medium 2026-06-02
CVE-2019-25719 Dräger Infinity M540 VG4.1.1 Spoofing and DoS via Network Message Handling — Infinity Acute Care System CWE-924 8.6 High 2026-06-02
CVE-2019-25717 Dräger Infinity Delta/Kappa Patient Monitors Unauthenticated Log File Disclosure — Infinity Delta CWE-538 4.3 Medium 2026-06-02
CVE-2019-25718 Dräger Infinity Explorer C700 Privilege Escalation via Kiosk Mode Bypass — Infinity Explorer C700 CWE-451 8.4 High 2026-06-01
CVE-2019-25716 Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet — Infinity Delta CWE-15 6.5 Medium 2026-06-01

This page lists every published CVE security advisory associated with Dräger. Each entry links to a detailed page with CVSS scoring, CWE classification, affected products and references. AI-generated Chinese analysis is provided for fast triage.