Philips — Vulnerabilities & Security Advisories 88

Browse all 88 CVE security advisories affecting Philips. AI-powered Chinese analysis, POCs, and references for each vulnerability.

CVE IDTitleCVSSSeverityPaused
CVE-2021-32993 Philips IntelliBridge EC 40 and EC 80 Hub Use of Hard-coded Credentials — IntelliBridge EC 40 HubCWE-798 8.1 High2021-12-27
CVE-2021-26248 Philips MRI 1.5T and 3T Incorrect Ownership Assignment — MRI 1.5TCWE-708 5.5 -2021-11-19
CVE-2021-42744 Philips MRI 1.5T and 3T Information Exposure — MRI 1.5TCWE-552 5.5 -2021-11-19
CVE-2021-26262 Philips MRI 1.5T and 3T Improper Access Control — MRI 1.5TCWE-286 6.8 -2021-11-19
CVE-2020-27298 Philips Interventional Workstations OS Command Injection — Interventional WorkspotCWE-78 6.5 Medium2021-01-20
CVE-2020-16247 Philips Clinical Collaboration Platform Configuration — Clinical Collaboration PlatformCWE-16 6.8 Medium2020-09-18
CVE-2020-16200 Philips Clinical Collaboration Platform Algorithm Downgrade — Clinical Collaboration PlatformCWE-757 6.5 Medium2020-09-18
CVE-2020-16198 Philips Clinical Collaboration Platform Protection Mechanism Failure — Clinical Collaboration PlatformCWE-693 5.0 Medium2020-09-18
CVE-2020-14525 Philips Clinical Collaboration Platform Improper Neutralization of Script in Attributes in a Web Page — Clinical Collaboration PlatformCWE-83 3.5 Low2020-09-18
CVE-2020-14506 Philips Clinical Collaboration Platform Cross-site Request Forgery — Clinical Collaboration PlatformCWE-352 3.4 Low2020-09-18
CVE-2020-16212 Philips Patient Monitoring Devices Exposure of Resource to Wrong Sphere — Patient Information Center iX (PICiX)CWE-668 8.8 -2020-09-11
CVE-2020-16220 Philips Patient Monitoring Devices Improper Validation of Syntactic Correctness of Input — Patient Information Center iX (PICiX)CWE-1286 6.5 -2020-09-11
CVE-2020-16216 Philips Patient Monitoring Devices Improper Input Validation — IntelliVue patient monitorsCWE-20 6.5 -2020-09-11
CVE-2020-16224 Philips Patient Monitoring Devices Improper Handling of Length Parameter Inconsistency — Patient Information Center iX (PICiX)CWE-130 6.5 -2020-09-11
CVE-2020-16228 Philips Patient Monitoring Devices Improper Check for Certificate Revocation — Patient Information Center iX (PICiX)CWE-299 6.4 -2020-09-11
CVE-2020-16222 Philips Patient Monitoring Devices Improper Authentication — Patient Information Center iX (PICiX)CWE-287 8.8 -2020-09-11
CVE-2020-16214 Philips Patient Monitoring Devices Improper Neutralization of Formula Elements in a CSV File — Patient Information Center iX (PICiX)CWE-1236 8.7 -2020-09-11
CVE-2020-16218 Philips Patient Monitoring Devices Cross-site Scripting — Patient Information Center iX (PICiX)CWE-79 4.3 -2020-09-11
CVE-2020-16239 Philips SureSigns VS4 Improper Authentication — SureSigns VS4CWE-287 4.9 Medium2020-08-21
CVE-2020-16241 Philips SureSigns VS4 Improper Access Control — SureSigns VS4CWE-284 6.3 Medium2020-08-21
CVE-2020-16237 Philips SureSigns VS4 Improper Input Validation — SureSigns VS4CWE-20 2.1 Low2020-08-21
CVE-2020-14518 Philips DreamMapper Insertion of Sensitive Information into Log File — DreamMapperCWE-532 5.3 Medium2020-08-21
CVE-2020-7360 Philips SmartControl DLL Hijacking — SmartControlCWE-427 7.4 High2020-08-13
CVE-2020-14477 Philips Ultrasound Systems Authentication Bypass Using an Alternate Path or Channel — Ultrasound ClearVueCWE-288 3.6 Low2020-06-26
CVE-2020-12023 Philips IntelliBridge Enterprise IBE Insertion of Sensitive Information into Log File — IntelliBridge Enterprise (IBE)CWE-532 2.0 Low2020-06-11
CVE-2019-10968 Philips Holter 2010 Plus 访问控制错误漏洞 — Philips Holter 2010 PlusCWE-477 6.0 -2019-07-24
CVE-2019-6562 Philips Tasy EMR 跨站脚本漏洞 — Philips Tasy EMRCWE-79 5.4 -2019-05-01
CVE-2018-8848 Philips e-Alert 安全漏洞 — e-Alert Unit (non-medical device)CWE-276 9.8 -2018-09-26
CVE-2018-8842 Philips e-Alert 安全漏洞 — e-Alert Unit (non-medical device)CWE-319 8.8 -2018-09-26
CVE-2018-8844 Philips e-Alert 跨站请求伪造漏洞 — e-Alert Unit (non-medical device)CWE-352 8.8 -2018-09-26

This page lists every published CVE security advisory associated with Philips. Each entry links to a detailed page with CVSS scoring, CWE classification, affected products and references. AI-generated Chinese analysis is provided for fast triage.